What was found
CRACKED FITTING ON FRONT SPAR TO ATTACH LINK OF INTI-ICE DUCT STA XRS=69 AT LT WING. REMOVE FITTING TREAT AND PAINT NEW FITTING AJUST AND DRILL NEW FITTING. INSTALLED NEW FITTING IAW SRM 51-30-5 AND 51-10-3, PAR 14 AND 21, DWG 9930529, REV F 5.