What was found
CORROSION ON COUNTERSINKS AT CENTRAL FUEL TANK ACCESS PLATE NR 2302C. COUNTERSINK HOLES WERE FOUND OUT LIMITS IAW SRM 51-22-2 ACCESS PLATE WAS REPLACED FOR A NEW ONE AND WILL BE INSTALLED UNDER CARD 5730-0655.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON COUNTERSINKS AT CENTRAL FUEL TANK ACCESS PLATE NR 2302C. COUNTERSINK HOLES WERE FOUND OUT LIMITS IAW SRM 51-22-2 ACCESS PLATE WAS REPLACED FOR A NEW ONE AND WILL BE INSTALLED UNDER CARD 5730-0655.