What was found
CORROSION WAS REMOVED ON LIGHTNING HOLE, AND FOUND OUT LIMITS ON CUSP WEB BS 744, BETWEEN X 56, TO X 60. REMOVED DAMAGE AND FABRICATED REPAIR IAW SRM 51-30-2, 53-05, FIG 131, A 51-103, PAR 14 AND 21 AND 38.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS REMOVED ON LIGHTNING HOLE, AND FOUND OUT LIMITS ON CUSP WEB BS 744, BETWEEN X 56, TO X 60. REMOVED DAMAGE AND FABRICATED REPAIR IAW SRM 51-30-2, 53-05, FIG 131, A 51-103, PAR 14 AND 21 AND 38.