What was found
CORROSION ON FUSELAGE SKIN AT RT FWD UNDERWING FILLET PANEL AREA BETWEEN BS 807 - 864 AND LONGERONS 28 - 30R. CORROSION WAS REMOVED AND REWORKED AREA WAS MEASURE STAY=824, LONGERON 30-29 RT IS 0.160" AND REMAINING'S 0.147". ON STA Y= 820-817 LONGERON 30-29, RT ORIGINAL'S 0.080" AND REMAINING'S 0.075" AND STA Y=813-807, LONG 29-28 RT ORIGINAL'S 0.170" AND REMAINING'S 0.160", THEREFORE IT'S WITHIN LIMITS, RESPECTIVELY. REWORKED AREAS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR.26,21 AND 14 AND 53-04, PAR 57.