What was found
CORROSION ON FUSELAGE SKIN AT RT OVERWING FILLET PANEL AREA BETWEEN BS 807 - 1033 AND LONGERONS 17 - 18R. REMOVE CORROSION AND REWORKED AREAS WERE MEASURED. ORIGINAL THICKNESS ON STA Y=927-950, LONG 18-17 RT IS 0.160" AND REMAINING'S 0.157" ON STA Y=960-1003 LONGERONS 18-17 RT 0.125" AND REMAINING'S 0.119"AND STA Y=1003-1020 ORIGINAL'S 0.063" AND REMAINING'S 0.060", THEREFORE THESE ARE WITHIN LIMITS IAW SRM 53-04, PAR.57. REWORKED AREAS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR. 26, 21 AND 14.