What was found
DURING INSPECTION, FOUND CRACK ON FRAME IN THE RIGHT EMERGENCY EXIT DOOR. REPLACED THE FRAME IAW SRM 51-72-11, DWGS D52279040, AND D52279010.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CRACK ON FRAME IN THE RIGHT EMERGENCY EXIT DOOR. REPLACED THE FRAME IAW SRM 51-72-11, DWGS D52279040, AND D52279010.