What was found
CORROSION ON COUNTERSINKS AT LT MAIN FUEL TANK ACCESS PLATE NR 1303 C. REWORKED IAW SRM 51-22-2A AND WAS TREATED IAW SRM 51-10-3, PAR. 21 AND BUSHING WERE FABRICATED IAW SRM 51-22-2A, PAR 6 AND WERE TREATED IAW SRM 51-10-3, PAR. 21 AND WERE INSTALLED IAW SRM 51-22-2A. ACCESS PLATE WAS TREATED IAW SRM 51-10-3 AND WAS PAINTED IAW PS 900-3-6, NR 36 AND WILL BE INSTALLED UNDER CARD 2800-0120, JOB 001-0386.