What was found
CRACKED ANGLE ON BEAM 1 AND DOOR STOP 12 OF LT FWD EMERGENCY EXIT DOOR. THE ANGLE WAS FABRICATED, TREATED, PAINTED, INSTALLED IAW SRM 51-30-1, 51-30-5, DWG 9957735, REV G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE ON BEAM 1 AND DOOR STOP 12 OF LT FWD EMERGENCY EXIT DOOR. THE ANGLE WAS FABRICATED, TREATED, PAINTED, INSTALLED IAW SRM 51-30-1, 51-30-5, DWG 9957735, REV G.