What was found
PITTING CORROSION ON EXTERNAL FUSELAGE SKIN BENEATH RUBSTRIPS FILLET PANELS FROM STA Y=1079 TO Y=1136 BETWEEN LONGERON 24 AND 30 RT. AREA WAS BLENDED OUT, MEASURED, TREATED, AND PAINTED AND CIC WAS APPLIED IAW SRM 51-10-3 AND 53-04, PAR 57. MEASURE REWORKED AREA ORIGINAL THICKNESS 0.130" AND REMAINING THICKNESS 0.105" THEREFORE IT IS WITHIN LIMITS IAW SRM 53-04, PAR 57.