What was found
CORROSION ON 6 PULLEY BRACKETS LOCATED Y=1338 AND RT LAVATORY FLOOR STRUCTURE. 6 PULLEY BRACKETS LOCATED Y=1338 AND RT LAVATORY FLOOR STRUCTURE WAS REPLACED IAW AMM 20-30-01-201. CONTROL CABLES WAS LOOSENED AND WAS RIGGING IAW AMM CHAPTER 27-20-00.