What was found
CRACK ON EXTERNAL SKIN AROUND EXTERNAL HANDLE CUTOUT AT FWD ENTRY DOOR. CRACK WAS FOUND OF 0.500" OF LENGTH. CRACK ON EXTERNAL SKIN WAS STOPPED DRILL IAW ERA 501106-14 MA REV-"B". HFEC WAS ACCOMPLISHED IAW NDT SPM 06-10-01.001 AND ERA 501106-14MA REV A. NO CRACKS WERE FOUND. DOUBLER REPAIR WAS FABRICATED IAW ERA 501106-14MA, REV "B". AREA WAS TREATED AND PAINTED. DOUBLER WAS PAINTED IAW SRM 51-10-3, PAR 14 AND 21. CONICAL WASHER'S WERE INSTALLED IAW ERA NR 501106-14MA, REV "B". DOUBLER WAS INSTALLED IAW SRM 51-30-2 AND ERA NR 501106-14 MA REV "B".