What was found
AFT CARGO PIT STA 1500, FLOOR CHANNEL SUPPORT ANGLE LBL 4" CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS. R & R SUPPORT ANGLE IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO PIT STA 1500, FLOOR CHANNEL SUPPORT ANGLE LBL 4" CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS. R & R SUPPORT ANGLE IAW SRM.