What was found
DURING INSPECTION, FOUND CORROSION ON CORNER FITTING FRAME 66, AT LEVEL STR 23L AT AFT GALLEY AREA L=0.196", W=0.075", D=0.001". REPLACED CORNER FITTING FRAME 66 AT LEVEL STR 23L AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.