What was found
DURING AD MANDATED INSPECTION, FOUND LT OVERWING FRAME AT STATION 696 CRACKED BELOW L18. REPLACED IAW DWG SR95530013, REV A, SRM 51-40-2 AND 51-40-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AD MANDATED INSPECTION, FOUND LT OVERWING FRAME AT STATION 696 CRACKED BELOW L18. REPLACED IAW DWG SR95530013, REV A, SRM 51-40-2 AND 51-40-05.