What was found
AFT PIT FLOOR SUPPORT STRINGER FROM STA 1445 TO 1500 LBL 13 CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R AT STA 1445 -1500, LBL 13 IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FLOOR SUPPORT STRINGER FROM STA 1445 TO 1500 LBL 13 CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R AT STA 1445 -1500, LBL 13 IAW SRM.