What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR STRUCTURE EVALUATED AND FOUND OUT LIMITS ON JOB 250 00-2032-DE, MEAURES OF REWORK ARE L=3.219", W=0.342", D = 0 .075" IN PASSENGER CABIN FROM FRAME 47 TO FRAME 64 - Y 1292. REPLACED SEAT TRACK FROM FRAME 47 TO FRAME 64 -Y1292 AND PERFORMED PERMANENT REPAIR AT LEVEL FR 55 + 9" IAW SRM 53-41-15 PARA 5.B, FIGURE 202, SRM 51-72-11 AND DWG D53476950, D53472000.