What was found
CORROSION ON CUSP WEB AND CLIPS BROKEN BETWEEN STA Y=636 TO Y=712 AND X=54 TO Y=60 LT SIDE. CUSP WEB ON Y=642-644 WAS ATTENDED WITH CARD 248, ZONE 201, NRC 20000048416. ON Y=698-706 WAS ATTENDED WITH CARD 250, ZONE 201, NRC 20000048417. CUSP WEB WITHIN LIMITS WAS REMOVED CORROSION AND TREATED AND PAINTED IAW SRM 51-10-3 PAR 26, 21, 14, 38. CLIPS WERE REPLACED IAW SRM 51-30-2,51-30-5 AND DWG 5913698, REV 1C. HFEC INSPECTION WAS PERFORMED ON REWORKED AREA. NO CRACK FOUND IAW ERA 511165-14MAR2015. MEASURE: ORIG 0.020" REMAINING ON STAY= 636 TO 643,Y= 645 TO 658, Y=660 TO 680, Y=682 TO 697, Y=702 TO 712 IS 0.018? WITHIN LIMITS.