What was found
SCRATCH ON LEFT FWD BORE OF RIB XOS 198 AT SLAT PANEL NR 2 RT WING. DAMAGE WAS REWORKED AND MEASURED, WITH DIAMETER INBD 0.940, 1 HOLE, THEREFORE WITHIN LIMITS OF MAXIMUM REWORK HOLE DIAMETER IAW SRM 57-02, PAR 9 C, 1. BUSHING WAS FABRICATED IAW SRM 57-02, PAR 9C, 2.