What was found
WORN LT CUSP WEB X=53 STA Y=284 AT FLOOR STRUCTURE. DAMAGE WAS DRILLED, TREATED, PAINTED, AND REPAIR PLUG WAS INSTALLED IAW SRM 51-10-3, PAGE N 14, 21, 53-01 FIG 1, SHEET 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WORN LT CUSP WEB X=53 STA Y=284 AT FLOOR STRUCTURE. DAMAGE WAS DRILLED, TREATED, PAINTED, AND REPAIR PLUG WAS INSTALLED IAW SRM 51-10-3, PAGE N 14, 21, 53-01 FIG 1, SHEET 2.