What was found
DURING INSPECTION, FOUND CORROSION ON WEB FRAME 16 AT LEVEL STR 23R AT FWD GALLEY AREA L=0.550", W=0.200, D=0.003". REPLACED WEB FRAME 16 LEVEL, STR 23R AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON WEB FRAME 16 AT LEVEL STR 23R AT FWD GALLEY AREA L=0.550", W=0.200, D=0.003". REPLACED WEB FRAME 16 LEVEL, STR 23R AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112780.