What was found
DURING INSPECTION, FOUND CORROSION ON CLEAT TIE LOCATED INTERNAL AREA IN FWD CARGO COMPARTMENT ON FRAME 28 BETWEEN STRINGER 43L TO STRINGER 43R, L=0.250, W=0.200, D=0, .002 . REPLACED CLEAT TIE LOCATED INTERNAL AREA IN FWD CARGO COMPARTMENT ON FRAME 28 BETWEEN STRINGER 43L TO STRINGER 43R IAW SRM 51-72-11 AND DWG D53231626.