What was found
CORROSION ON RT CABIN FLOOR STRUCTURE CUSP WEB STA Y= 438-440, Y=459-461, Y= 480, Y=489 BETWEEN X=-54 TO X=-60. UPPER AND LOWER SURFACES. CUSP WEB STA Y=438-440, Y=459-461 WERE REPAIRED IAW SRM 53-05, FIG 131A-13. CUSP WEB BETWEEN Y=479-484 WAS REPAIRED IAW SRM 53-05, FIG 131A. DAMAGE AT Y=489 WILL BE ATTENDED WITH CARD 309, ZONE 201.