What was found
CORROSION ON RT CABIN FLOOR CUSP WEB FROM STA Y=785 TO Y= 905 BETWEEN X=-48 AND X= -60 UPPER ANDLOWER SURFACES AND DOUBLER REPAIR. CORROSION WAS REMOVED IAW SRM 51-10-3 PAR 14, 21, 26. STA Y=897-902 WAS FOUND OUT OF LIMITS AND WILL BE REPAIRED WITH NRC 314 ZONE 201 AND DOUBLER WITH CORROSION WILL BE REPLACED WITH NRC 315, ZONE 201.