What was found
DURING MAINTENANCE ACTIVITIES. DAMAGE BORES ON RIBS STA XOS 286, 332 AND 380 AT RT SLAT PANEL NR 3. DAMAGE ON RIB STA XOS=332 WAS REWORKED AND MEASURED WITH ID 0.938, 4 HOLES, THEREFORE LIMITS OF MAXIMUM REWOK HOLE DIAMETER IAW SRM 57-02, PAR 9 C (1). BUSHINGS WERE FABRICATED AND INSTALLED IAW SRM 57-02, PAR. 9 C, 1, 2. DAMAGE ON RIB`S STA XOS= 286, 380 WERE REPAIRED IAW AND ER/A 533331-14 REV ORIGINAL.