CRACKED FLOOR SUPPORT AT BS 965 AND 984, X=-30 TO X=-37 AT RT CABIN FLOOR STRUCTURE. CRACKED FLOOR SUPPORTS WERE REMOVED DRILLED ADJUSTED AND INSTALLED IAW SRM 51-10-3, PAR 13, 14 AND 21, SRM 51-30-5 AND 53-14-3 FIG 12, 51-10-4.