What was found
CORROSION ON LT CUSP WEB UPPER AND LOWER SURFACE FROM STA Y=1250 TO Y=1271, STA Y=1271 TO Y=1287 BETWEEN X=54 TO X=60 AT CABIN FLOOR STRUCTURE. CORROSION WAS ATTENDED, REMOVED; MEASURED AND FOUND WITHIN LIMITS BETWEEN Y=1250-1271 BUT AT Y=1247 IT'S 0.035" AND SO OUT OF LIMITS, AND THIS WILL BE ATTENDED WITH CARD 313, ZONE 201.