What was found
DURING INSPECTION, FOUND SCRATCH ON STATIC PORT LOCATED BETWEEN FR 3 TO FR 4 LT SIDE PANEL ON LOWER FUSELAGE. PERFORMED PERMANENT REPAIR PRINCIPLE 1 ON STATIC PORT LOCATED BETWEEN FR 3 TO FR 4 LT SIDE SKIN FUSELAGE IAW SRM 53-11-11, PARA 5A, FIG 203, PAGES 215/218.