What was found
DURING INSPECTION, FOUND CORROSION ON LOWER SILL AT STR 23R AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 68, L=0.500", W=0.300", D=0.002". REPLACED LOWER SILL AT STR 23R AFT GALLEY AREA FROM FRAME 66 TO FRAME 68 IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON LOWER SILL AT STR 23R AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 68, L=0.500", W=0.300", D=0.002". REPLACED LOWER SILL AT STR 23R AFT GALLEY AREA FROM FRAME 66 TO FRAME 68 IAW SRM 51-72-11.