DURING INSPECTION FOUND EMERGENCY LIGHT IS INOPERATIVE AT SEAT 16,17,18 F/E/D BY EMERGENCY DOOR. MAINTENANCE REPLACED BATTERY PACK LOCATED BY OVERWING SCAPE DOORS IAW AMM 33-51. LIGHTS OPS CK NORMAL.