What was found
DURING INSPECTION, FOUND CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR ON EXTERNAL SKIN ON LOWER FUSELAGE ON FRAME 72+11" AND STR 34. PERFORMED PERMANENT REPAIR ON EXTERNAL SKIN LOWER FUSELAGE BETWEEN FRAME 72 TO FRAME 75 AND BETWEEN STR 31R TO STR 32L IN AFT FUSELAGE IAW SRM 53-51-29, PARA 5.B, FIG 202.