What was found
CORROSION ON INTERCOSTAL STA Y=1310 BETWEEN LONGERON 27LT-28LT AT AFT CARGO COMPARTMENT. REPAIR PARTS WERE FABRICATED, DAMAGE ON INTERCOSTAL WAS REMOVED, FABRICATED REPAIR PARTS WERE TREATED AND PAINTED, REPAIR PARTS WERE INSTALLED, INTERCOSTAL WAS INSTALLED AND CIC WAS APPLIED IAW SRM 51-30-2.