As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON HOLE COUNTERSINKS AND FAYING SURFACE AT LT FUEL TANK ACCESS PANEL 1357C. CORROSION ON HOLES COUNTERSINK ACCES PANEL 1357C WAS REMOVED. THE MAX DIAMETER ALLOWED IS 0.532 AND FOUND 3 HOLES DAMAGED ADJACENT WITH .554, .551 AND .538. THE MAX BUSHING PER DOOR ALLOWED ARE 2, THEREFORE, ACCESS PANEL WAS REPLACED IAW SRM 51-22-2A. LP 1889935