What was found
CRACKED FITTING STOPS 2, 3, 5 ON FWD FRAME CUTOUT OF C2 DOOR. STOP FITTINGS WERE REMOVED IAW SRM 51-30-1 AND 51-30-5 , STOPS FITTINGS WERE DRILLED IAW SRM 51-10-4, NEW STOP FITTINGS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14 , NEW STOP FITTINGS WERE INSTALLED IAW SRM 51-30-1 AND 51-30-5. LP 1890527