What was found
CORROSION ON INTERCOSTAL FROM STA Y=1147 TO Y= 1155 BETWEEN LONGERON 30-29 RT. INTERCOSTAL CLIPS AND SUPPORT WERE REMOVED IAW SRM 51-30-2 INTERCOSTAL WAS FABRICATED IAW DWG 936071 NEW INTERCOSTAL WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14 INTERCOSTAL WAS INSTALLED IAW SRM 51-30-2, CLIPS AND SUPPORT WERE INSTALLED IAW SRM 51-30-2, 51-30-5. LP 1894782.