What was found
PREVIOUS REPAIR SPLICE AT STA 1280, FRAME STR 10L IS GOUGED. REMOVED DAMAGE ANGLE, FABRICATED NEW ANGLE FROM 70750 .071 PO ST-00003940. HEAT TREATED TO 7075T6 IAW FAS FORM, FAS 0155, REV 12, DIM 13".500 X 4".250, AND INSTALLED NEW ANGLE IAW SRM 53-00-07. REPAIR 1, FIG 202, INSTALLED REPAIR ID IAW PS 900-5-1. LP1894803.