What was found
DURING INSPECTION, FOUND CORROSION FOUND BETWEEN STR 42L AND 43L BETWEEN 56-57 REF PRI 53-5226-14. INSTALLED DOUBLER IAW PRI 535226-12, VER 1, 2 , 874907.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION FOUND BETWEEN STR 42L AND 43L BETWEEN 56-57 REF PRI 53-5226-14. INSTALLED DOUBLER IAW PRI 535226-12, VER 1, 2 , 874907.