What was found
FOUND 1 SCRATCH ON EXTERNAL SURFACE OF BULK CARGO DOOR AT STA 1430 TO 1440 BETWEEN S-25L & S-26L. 1 SCRATCH REMOVED AND MEASURED THE REMAINING THICKNESS IS 0.068". ORIGINAL THICKNESS IS 0.071" FOUND WITHIN LIMIT IAW SRM 52-30-01, FIG 101. HFEC INSPECTION CARRIED OUT IAW NDTM D634T301, REV 109, PART 6. 51-00-19 ON REWORKED AREA AND FOUND NO CRACK EVIDENT. REWORKED AREA PROTECTED IAW SRM 51-20-01. 1916322.