What was found
FOUND CRACK AT FS 2370 S-15L. MEASURED CRACK AND TOTAL LENGTH IS 1.3750". REMOVED DAMAGE IAW SRM 53-00-01, REPAIR 1. PERFOMRED HFEC, DAMAGE CONTAINMENT, OF CUTOUT IAW NDT MANUAL 51-00-00, PART 6. PERFORMED BHEC OF EXISTING FASTENERS IAW NDT 51-00-00, PART 6. NO CRACKS INDICATIONS NOTED. FABRICATED DOUBLER AND FILLER TREATED AND PRIMED INSTALLED REPAIR IAW SRM 53-00-01, REPAIR 1. APPLIED TOP COAT. THIS REPAIR IS A CATEGORY B REPAIR WITH BLIND RIVETS IAW TABLE IV REPETITIVE INSPECTION WITIN 3,000 CYCLES, INTERVAL HFEC COMPLETE. REQUIRED INSPECTION COMPLETE.