What was found
MAIN CABIN, CORROSION NOTED ON CREASE BEAM , STA 1380 S17R 8" X 3". REMOVED SECTION OF WEB AT STA 1380 TO 1400 RT. WEB FOUND OUT OF LIMITS IAW SRM 53-60-13 WITH MORE THAN 80 PERCENT MATERIAL LOSS. FABRICATED NEW WEB FROM 7075T6. 0.040" DIM 7" X 19.5". PART ALODINED, PRIMED, TOP COATED & INSTALLED ALL IAW SRM 51-20-01, 51-40-02 & DWG 149N5590 REV-R. LP1931185.