What was found
MAIN CABIN FLOORBEAM BS 324, RBL 56 IS CORRODED. CUT OF SECTION OF UPPER TEE AT RBL 34. LOCATED & DRILLED NEW TEE. FABRICATED TWO ANGLES. FABRICATED TWO STRAPS. HEAT TREATED ALL PARTS IAW FAS FORM FAS0115, REV.012. COMPLIED WITH HFEC INSPECTION OF CUT & OPEN HOLES IAW NDTM PT 6, 51-00-19 & 51-00-16 A 15270. ALL PARTS ALDODINED, PRIMED, TOP COATED & INSTALLED IAW SRM 53-10-08, REP 1.