As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ACFT SERVICE CHECK, FOUND EMERGENCY LIGHTING INOPERATIVE AT ROWS 33-36, 37-39. FOUND POWER SUPPLY AT FS 1334 OVERHEAD INOPERATIVE 1 OF 2. ABOVE CEILING PANEL R & R LT POWER PACK SUPPLY ASSY AND LOOSE PLUG ASSY. "D9104J" REF FS 1210 WIRING DIAGRAM 33-51-22. CEILING PANELS INSTALLED FS 1334. OK FOR SERVICE. EMERGENCY LIGHTS CK OK.