What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y1292 AT LEVEL FRAME 16. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112812.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y1292 AT LEVEL FRAME 16. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112812.