What was found
DURING INSPECTION, FOUND CORROSION ON SPLICE AT AFT GALLEY AREA ON STRINGER 27L FRAME 67. REPLACED THE STRINGER SPLICE IAW SRM 51-72-11, DWG D5348002 AND ER/A NR 535322-14, REV 0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON SPLICE AT AFT GALLEY AREA ON STRINGER 27L FRAME 67. REPLACED THE STRINGER SPLICE IAW SRM 51-72-11, DWG D5348002 AND ER/A NR 535322-14, REV 0.