What was found
AFT CARGO FLOOR STRUCTURE, STRINGER 27R HAS CORROSION UNDER TWO NUT PLATES AT BS 1510. CUT OUT DAMAGE, FABRICATED REPAIR ANGLE & INSTALLED IAW ERA 332525-14MA & SRM 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FLOOR STRUCTURE, STRINGER 27R HAS CORROSION UNDER TWO NUT PLATES AT BS 1510. CUT OUT DAMAGE, FABRICATED REPAIR ANGLE & INSTALLED IAW ERA 332525-14MA & SRM 51-20-01.