What was found
CORROSION ON FLOORBEAM Y1292 BETWEEN FRAME 65 TO FRAME 66 AT AFT GALLEY AREA L=0.345", W=0.246", D=0.003", SSI 534147. REPLACED FLOORBEAM LOCATED BETWEEN FRAME 64 TO FRAME 66+5", Y1292 IAW SRM 51-42-11 AND DWG D53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM Y1292 BETWEEN FRAME 65 TO FRAME 66 AT AFT GALLEY AREA L=0.345", W=0.246", D=0.003", SSI 534147. REPLACED FLOORBEAM LOCATED BETWEEN FRAME 64 TO FRAME 66+5", Y1292 IAW SRM 51-42-11 AND DWG D53472000.