What was found
AFT UTILITY, FLOORBEAM CORRODED, -Y1292, FRAME 68 - 69, REMOVED CORROSION IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED FLOORBEAM IAW SRM 51-42-11 AND SRM 51-44-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY, FLOORBEAM CORRODED, -Y1292, FRAME 68 - 69, REMOVED CORROSION IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED FLOORBEAM IAW SRM 51-42-11 AND SRM 51-44-11.