What was found
CORROSION ON LOWER SILL AT AFT GALLEY AREA ON FRAME 66 AND STR 23R. REPLACED LOWER SILL IAW SRM 51-72-11 AND DWG D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON LOWER SILL AT AFT GALLEY AREA ON FRAME 66 AND STR 23R. REPLACED LOWER SILL IAW SRM 51-72-11 AND DWG D53480505.