What was found
CORROSION ON RT CUSP WEB BS 1079-1089 BETWEEN X=56 - X=60. FASTENERS WERE REMOVED, FITTING BS 1097 LT WAS REMOVED, DAMAGE WAS REMOVED, NEW REPAIRS PARTS WERE FABRICATED, REPAIR PARTS WERE TREATED AND PAINTED, REPAIRS PARTS ANGLE AND FITTING WERE INSTALLED, AND CIC WAS APPLIED IAW SRM 51-30-5, 51-30-1, 53-05, FIG 131A, 51-10-3, PAR 14 AND 21, 51-30-2 AND 51-10-3, PAR 38.