What was found
CORROSION AND SCRATCHS ON RIB HOLES NR 2 BS XOS= 240 WERE REMOVED IAW SRM 57-02 PAR 9. REWORKED HOLES WERE MEASURED INBD LUG FWD HOLE 0.939" AND AFT HOLE 0.941". BUSHINGS WERE FABRICATED IAW SRM 57-02, PAR 9, C, TABLE 1, 1, 2. BUSHINGS WITH OD 0.942" BUSHINGS WITH OD 0.940", 1 EA, BUSHINGS WITH OD 0.939", 2 EAS. BUSHINGS AND REWORKED AREAS WERE TREATED IAW SRM 51-10-3, PAR 21. NEW BUSHINGS WERE INSTALLED IAW SRM 57-02 PAR 9. USED TOOL: CALIPER DIGITAL GD-573 AJM DUE DATE 26-SEP-15. PRIMARY STRUCTURE.