What was found
CORROSION ON RT CUSP WEB BETWEEN X=-54 TO -60 AND BS 1098 - 1117, 1136 - 1155, 1155 - 1174, 1174 - 1193, 1193 - 1212 AT PAX CABIN FLOOR STRUCTURE. CUSP WEB REMOVED IAW SRM 51-30-2, 51-30-5. A NEW CUSP WEB WAS DRILLED IAW SRM 51-10-4 & DWG 9930612, REV, THE NEW CUSP WEB WAS INSTALLED IAW SRM 51-30-2, 5130-5.